NUEVODiseña tu máquina gratis: lista completa de componentes en 2 minutos Empezar →Diseña tu máquina gratis → NEWDesign your machine for free: full component list in 2 minutes Start →Design your machine free →

Dual-Channel Conductivity / TDS Controller – Panel Mount 96×48, 2 Sensors, 4–20 mA Output, High/Low Alarm, 110 VAC

$192.99

96×48 mm panel-mount conductivity and TDS controller with two 1/2″ sensors to monitor water in and out at the same time. 4–20 mA output, high/low alarm relay, automatic temperature compensation, 110 VAC supply.

Request a quote / bulk pricing

Buying for a business or need several units? Send us the quantity and destination and we will reply with a quote.

SKU: ABX-AE-532017 Category:
Dual-Channel Conductivity / TDS Controller – Panel Mount 96×48, 2 Sensors, 4–20 mA Output, High/Low Alarm, 110 VAC
Technical specification sheet · automationbotx.com
SKUABX-AE-532017
Inputs2 conductivity sensors (1/2")
Conductivity range0.0–9999 µS/cm; 0.0–20.0 mS/cm
TDS range0.0–9999 ppm; 0.0–10.0 ppt
Resolution0.1 (0.0–99.9); 1 (100–9999)
Accuracy±2 %
Temperature compensationautomatic, 1–65 °C
Output4–20 mA
Alarmhigh and low limit, ON/OFF relay
Displaybacklit LCD
Sensor cable3 m
Ambient-5 to 50 °C, ≤85 % RH
Power supply110 VAC
Size96 × 48 × 100 mm (W × H × D)

Data as published in this listing by the manufacturer or supplier. Price, stock and shipping are shown above.

Ask about this product

Compatibility, wiring, a value that is missing? Send your question and we reply by email. Prefer to call? +1 346 283 9580.

We use your email only to answer this question.

Description

Online conductivity and TDS monitor for RO and water-treatment skids, boiler feed and rinse water. The two sensors measure inlet and outlet water at the same time, and the backlit LCD shows both values; the high/low limit alarm relay can switch a pump, valve or warning light.

Specifications (as listed by the supplier)

  • Inputs: 2 conductivity sensors (1/2″)
  • Conductivity range: 0.0–9999 µS/cm; 0.0–20.0 mS/cm
  • TDS range: 0.0–9999 ppm; 0.0–10.0 ppt
  • Resolution: 0.1 (0.0–99.9); 1 (100–9999)
  • Accuracy: ±2 %
  • Temperature compensation: automatic, 1–65 °C
  • Output: 4–20 mA
  • Alarm: high and low limit, ON/OFF relay
  • Display: backlit LCD
  • Sensor cable: 3 m
  • Ambient: -5 to 50 °C, ≤85 % RH
  • Power supply: 110 VAC
  • Size: 96 × 48 × 100 mm (W × H × D)

Notes

  • Supplied in the 110 VAC version for North America.
  • The supplier does not state the sensor cell constant or the relay contact rating; ask us before ordering if your application needs them.
  • For several units, request a written quote on our Wholesale & Bulk Orders page.

Reviews

There are no reviews yet.

Be the first to review “Dual-Channel Conductivity / TDS Controller – Panel Mount 96×48, 2 Sensors, 4–20 mA Output, High/Low Alarm, 110 VAC”

Your email address will not be published. Required fields are marked *