SONGGER QT-10H2 Hydrogen (H2) Gas Transmitter, 0-1000 ppm | 4-20 mA, 0-10 V or RS485 Modbus, 10-30 VDC, IP65
$200.99
Wall-mount hydrogen gas transmitter for battery rooms and UPS enclosures. 0-1000 ppm, 1 ppm resolution, ±5% FS, output 4-20 mA, 0-10 V or RS485 Modbus, 10-30 VDC, IP65, as listed by the supplier.
Request a quote / bulk pricing
Buying for a business or need several units? Send us the quantity and destination and we will reply with a quote.
Technical specification sheet · automationbotx.com
| SKU | ABX-AE-560125 |
|---|---|
| Manufacturer part number | QT-10H2 |
| Output (options) | 4-20 mA · 0-10 V · RS485 |
| Range (options) | 0-1000 ppm |
| Choose the output for your input card | 4-20 mA, 0-10 V or RS485 (Modbus address 1-255, baud rate 1200-115200). |
| Brand | SONGGER |
| Model | QT-10H2 |
| Gas | Hydrogen (H2) |
| Range | 0-1000 ppm |
| Output | 4-20 mA, 0-10 V or RS485 |
| Supply | 10-30 VDC |
| Power consumption | 0.12-0.9 W |
| Accuracy | ±5% FS |
| Resolution | 1 ppm |
| Stability | Under 2% of signal per month |
| Response time | 70 s or less (1000 ppm) |
| Preheating time | 5 min or more |
| Operating temperature | -20 to 50 °C |
| Operating humidity | 15-90% RH non-condensing |
| Pressure range | 90-110 kPa |
| Housing | IP65, wall mount, no display |
| Dimensions | 110 × 85 × 44 mm |
| Hydrogen is lighter than air | the supplier does not give a mounting height, so follow your site's gas-detection layout (usually high on the wall or near the ceiling above the batteries). |
Data as published in this listing by the manufacturer or supplier. Price, stock and shipping are shown above.
Ask about this product
Compatibility, wiring, a value that is missing? Send your question and we reply by email. Prefer to call? +1 346 283 9580.
Description
The SONGGER QT-10H2 is a wall-mount hydrogen (H2) gas transmitter with a built-in probe in an IP65 housing. It gives a PLC, RTU or data logger a continuous H2 reading in ppm for rooms where hydrogen can collect: battery rooms and UPS enclosures with lead-acid banks at compressor stations, control buildings and telecom shelters, and chemical or electrolysis areas.
Key points
- Range 0-1000 ppm with 1 ppm resolution and ±5% FS accuracy, as listed by the supplier.
- Choose the output for your input card: 4-20 mA, 0-10 V or RS485 (Modbus address 1-255, baud rate 1200-115200).
- Wide 10-30 VDC supply and 0.12-0.9 W consumption, suitable for 24 VDC panels and solar-powered RTUs.
- IP65 waterproof, dustproof and anti-corrosion housing, 110 × 85 × 44 mm.
- Response time 70 s or less at 1000 ppm; preheat 5 minutes or more after power-up.
Specifications (as listed by the supplier)
- Brand: SONGGER
- Model: QT-10H2
- Gas: Hydrogen (H2)
- Range: 0-1000 ppm
- Output: 4-20 mA, 0-10 V or RS485
- Supply: 10-30 VDC
- Power consumption: 0.12-0.9 W
- Accuracy: ±5% FS
- Resolution: 1 ppm
- Stability: Under 2% of signal per month
- Response time: 70 s or less (1000 ppm)
- Preheating time: 5 min or more
- Operating temperature: -20 to 50 °C
- Operating humidity: 15-90% RH non-condensing
- Pressure range: 90-110 kPa
- Housing: IP65, wall mount, no display
- Dimensions: 110 × 85 × 44 mm
Before you order
- This listing is the standard wall-mount model with a built-in probe and no display. The output is chosen in the selector.
- Hydrogen is lighter than air: the supplier does not give a mounting height, so follow your site’s gas-detection layout (usually high on the wall or near the ceiling above the batteries).
- Not rated for hazardous (classified) areas: mount it outside classified zones or follow your site rules. No third-party certification is included.
- It is a monitoring input, not a certified life-safety gas detector. Use your PLC or a relay to trigger ventilation or an alarm if needed.
- To log and trend the reading remotely in read-only mode, see AutomationBotX Cloud (free up to 10 machines).
Additional information
| Output | 4-20 mA, 0-10 V, RS485 |
|---|---|
| Range | 0-1000 ppm |









Reviews
There are no reviews yet.